Calculated Industries 4087 Manuel

Naviguer en ligne ou télécharger Manuel pour Pompes à eau Calculated Industries 4087. Calculated Industries 4087 Hardware manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
TeleFlow™
Standard ACCOL
Load
(NOTE: This manual was formerly entitledTeleFlow
Standard ACCOL Load and Menus', TMS menus are now
documented in appendices of the TeleFlow hardware manual.)
D4087 Issue: December, 2000
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - Standard ACCOL

TeleFlow™Standard ACCOLLoad(NOTE: This manual was formerly entitled ’TeleFlow™Standard ACCOL Load and Menus', TMS menus are nowdocumented in appe

Page 2

BLANK PAGE

Page 3

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-1 Standard ACCOL LoadOverviewThe TeleFlow Standard load is a an ACCOL load (ACL file) that is inte

Page 4 - Training Courses

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-2Configurable 1, 2, 5, 15, and 60 second calculation interval.Pulse counting an

Page 5

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-3 Standard ACCOL Loadobtained by summing the Extensions computed every second during the intervala

Page 6

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-4Input Override and Calibration ModeThe 'in use' signals can be &apos

Page 7 - Table of Contents

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-5 Standard ACCOL LoadWhen Sampler output is enabled:DO 1 - Pulse output based on volume (to drive

Page 8

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-6Communications Port AssignmentsPORT #1 - Pseudo-slave local port, 19200 bps.PO

Page 9 - Chapter 1 - Introduction

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-7 Standard ACCOL LoadThe flow control is active and not close to the setpoint.Super-compressibilit

Page 10 - BLANK PAGE

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-8the total cleared for the next period. The running total is not cleared; it ac

Page 11 - Overview

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-9 Standard ACCOL LoadLow-Flow Cut-OFFThe 'live' Differential pressure is always compared

Page 12 - TeleFlow™ Standard ACCOL Load

The information in this document is subject to change without notice.Every effort has been made to supply complete and accurate information.However,

Page 13 - Temperature (T)

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-10file.DATE/TIMELOCAL SEQUENCE NUMBERGLOBAL SEQUENCE NUMBERAVERAGE DP INH2OAVER

Page 14 - Digital Outputs

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-11 Standard ACCOL LoadGain 1Integral 1 repeat/minDerivative 0 minsDeadband 0Valve travel 30 secsPu

Page 15 - Auxiliary Analog Input

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-12commands sent to the modem (i.e. initialization, phone number) are defined by

Page 16 - Gas Flow Calculations

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-13 Standard ACCOL LoadAudit/Event LogThe EAUDIT module (in Task 0) is set up to collect both alarm

Page 17

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-14DP Full scale pressureDP Pressure zeroSP Full scale pressureSP Pressure zeroT

Page 18 - Gas Energy Calculations

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-15 Standard ACCOL LoadN2CO2C2C3H2OH2SH2COO2IC4NC4IC5NC5C6C7C8C9C10HEARSampler enableSampler volume

Page 19 - Archive Files

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-16Radio local comm. timeRadio local timeoutRadio time per nodeRadio time per gr

Page 20 - Flow Control

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-17 Standard ACCOL LoadBase TemperatureFlowing ViscosityRatio of Specific HeatTap LocationTap TypeD

Page 21 - Radio Control

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-18Next start hourNext stop dateNext stop hourLIST 15 AGA8 Gross ConfigSpecific

Page 22 - Power and Load Status Alarms

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-19 Standard ACCOL LoadFtbFgFtfFaFrYFbFpvC-primeExtensionLIST 18 Communication configurationNetwork

Page 23 - Audit/Event Log

iA Few Words About Bristol BabcockFor over 100 years, Bristol has been providing innovative solutions for the measurement and control industry.Our pro

Page 24

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ Standard ACCOL Load2-20Dial on Auxiliary input alarm enableDial on Charger alarm enableDial on Nomin

Page 25

Chapter 2 - TeleFlow Standard ACCOL LoadTeleFlow™ 2-21 Standard ACCOL LoadBackup battery voltsPC board temperatureAuxiliary inputTotal pulsesPulse Fre

Page 26

BLANK PAGE

Page 27

Appendix AModifying the TeleFlow Standard ACCOL (TSA) LoadTeleFlow™ A-1 Standard ACCOL Load and MenusModifying or Replacing the TeleFlow Standard ACC

Page 28

Appendix AModifying the TeleFlow Standard ACCOL (TSA) LoadTeleFlowTM Standard ACCOL Load and MenusA-23 Analog Input Board with 1, 4,5, or 8 points (or

Page 29

READER RESPONSE FORMPlease help us make our documentation more useful to you! If you have acomplaint, a suggestion, or a correction regarding this man

Page 30

an FKI company1100 Buckingham StreetWatertown, CT 06795Telephone: (860) 945-2200

Page 31

iiThe Application Support Group also maintains a bulletin board for downloading software updates tocustomers. To access the bulletin board, dial (860)

Page 32

iiiWho Should Read This Document?This document is intended to be read by EGM 3530-xx TeleFlow users who areusing the standard software accompanying th

Page 34

vTable of ContentsChapter 1 - Introduction 1-1Chapter 2 - TeleFlow™ Standard ACCOL Load 2-1Appendix A - Modifying the TeleFlow™ Standard ACCOL Load A-

Page 36 - Telephone: (860) 945-2200

Chapter 1 - IntroductionTeleFlow™ 1-1 Standard ACCOL LoadWhat is the TeleFlow™ Standard ACCOL Load?The TeleFlow™ Standard ACCOL Load is included on t

Commentaires sur ces manuels